![]() Moved the gas to Pilot, depressed, got mV up to 500. But after that initial fire it hasn't fired up again.Ĭhecked today, pilot light is still lit. The burner ran for a few minutes and produced warm water. Voltage dropped to 240 mV, but the burner did fire on. ![]() Yesterday sat down and took some notes as I went through.ġ) Turned the gas valve from Off to PilotĢ) Depressed gas valve and pushed red lighter buttonĤ) Measured the voltage from the millivolt system, jumped from 0 to 540 in about 45s to a minuteĥ) Stopped depressing the gas button for pilot, voltage dropped to 340 mVĦ) Switched from Pilot to On, voltage stayed the sameħ) Flicked the "ON" switch on the front. Had some time to work on this again from scratch. So with a new pilot assembly and gas valve I should have a working heater in an old enclosure. The techs told me this thing was old, but the burners are good and the heat exchanger is good. If I called them they'd charge me a usurious rate to look at their broken work. Used On Hayward H-Series Electronic ED2 Heater. (Using the included adapter, the new style temp sensor will work in IDL heaters as well as FD heaters) Used On Hayward H-Series Low NOx Induced Draft Heater. Details: Hayward Pool Products Part Number IDXLTER1930 also replaces FDXLTER1930. this model features an easy-to-use digital control panel and remote. 20 Thermistor Temperature Sensor Item Number: IDXLTER1930. The company that "fixed" it by replacing the parts makes the term incompetent seem like a compliment. The Hayward H200 Pool Heater is packaged in a box that measures roughly 5 feet by 2. I believe this is my issue because 200 mV isn't enough to open the gas valve to fire up the burner.ġ) Should voltage drop once I stop pressing the pilot light button?Ģ) Even though voltage drops it's steady across the TH connections, meaning I think my wiring is good.ģ) What voltage should this thing be at to get the gas valve open? Does it only need to be 500 mV initially?Ĥ) Why would this have worked recently then stopped? Nothing changed except the pilot would shut itself off. The second I let go and the button pops up mV drops down to the 200 range. This is with the gas button pressed down. I can fire up the pilot light and when I measure I can get 522 mV from the pilot generator. I have a multimeter and started to mess with this thing. Walked through the troubleshooting chart and slightly increased pressure and pilot stays lit. ![]() You should also ensure that the igniters wires to the control board are. My dad has some HVAC experience and mentioned the gas pressure was probably too low. In this article, Ill cover the most common causes of the Hayward heater IF. I tried to fire it up a few times recently and the pilot light would shut off. Then about a month later to bump it up a few degrees, it's been off since then. I used the heater twice, the first time to warm the water from 74 to 84 to get the pool open. Hayward HAXCPA3203 H200 Control Panel Assembly Replacement for Hayward Pool Heater by Hayward Write a review How customer reviews and ratings work Sign in to filter reviews 5 total ratings, 4 with reviews From the United States Fishery great price it was a bout half of what other. Received a new pilot generator assembly and gas valve. It didn't work when we opened the pool, but since we'd lived here less than a year the warranty covered it. Have a 2001 Hayward H200 heater that came with the house.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |